IS420UCSBH1A
IS420UCSBH1A
IS420UCSBH1A
·ATS22 软起动器
·ATS48 软起动器
·ATV12 变频器
·ATV303 变频器
·ATV312 变频器
·ATV32 变频器
·ATV71 Lift 电梯专用变频器
·ATV212 变频器
·ATV61 变频器
·ATV71 变频器
·ATV61 Plus 柜式变频器
·ATV71 Plus 柜式变频器
·AFE 有源前端四象限运行选件
·ATV1100 中压变频器
·对话工具与通讯 使用Microdrive V 进行串行通讯可以有2 种方式:
1. 使用某种面向字符协议的RS232 串行通讯 (RS485 可备选)
2. 可选的Fieldbus 接口模块。
使用Microdrive V 通讯的性质也可以分为2 类:
1. 实时控制和检测,例如设定速度基准、监测变频器状态等
2. 修改变频器参数值
standard of IEC61131-3, and has
There are high-performance graphics editing functions:
– Function Block Diagram (FBD)
-Ladder Diagram (LD)
– Instruction List (IL)
– Sequence Control Chart (SFC)
. Structured Text (ST)
●Extensive function block library, user-defined function blocks can also be added
Added to it, the macro library and graphic symbols can be customized for the user.
Blocks can create graphics and operator panels.
●Any standard can be integrated by means of GSD file import
PROFIBUS-DP and PA devices, and through user-defined pairing
dialog box to design the configuration window for these devices.
●Profibus field controller can be integrated through FDT/DTM technology
line equipment
system structure
The Freelance 800F process control system is divided into operator levels
and process control level. The operator level contains controls for operation and display.
Archiving and logging, trending and alarming functions. Controller executes open loop
and closed loop control function.
Freelance 800F DigiVis Operator Level
DigiVis operator stations use PC hardware, either standard commercial
Business PCs can also be industrial-grade PCs and run on Micro-
under soft Windows operating system. DigiVis supports dual-screen display operation
operating technology, that is to say, two operations can be performed using one PC
station and operate with a mouse and a keyboard.
Operator level can install one engineering station and several operators
stand. ControlBuilderF engineering station configures and adjusts the system
Mode. Usually, we can use portable devices such as notebooks to
The system is now configured in the office and on site. Operator-level PC
Can also be used as an engineer station. Engineer standing during system uptime
Intervals can be closed without a permanent connection to the system.
Freelance 800F Process Control Stage
At the process control level, the Freelance 800F system can be controlled by
It consists of a number of process control stations connected to I/O units. you can choose this
Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy
redundant) or non-redundant mode. Modular pluggable input/output modules
Blocks are freely selected and used according to the type and number of system process signals.
AC800F controller