IS200PICHG1A
IS200PICHG1A
IS200PICHG1A
介绍 Modicon X80 计数模块 BMXEHC0200 的软硬件实施。
计数模块是标准格式模块,能够以最大频率 60 KHz 计数传感器的脉冲 (BMX EHC 0200)。
BMX EHC 0200 模块中有 2 个通道。
每个通道上使用的传感器可以是:
·24 VDC 2 线接近传感器
·具有 10/30 VDC 输出和推挽输出的递增信号编码器。介绍了如何通过使用 EcoStruxure Control Expert 的 Modicon M340 运用运动功能块 (MFB)。这些功能块通过使用 CANopen 总线简化了对伺服驱动器和伺服放大器的管理。
为了将 MFB 与 EcoStruxure Control Expert 软件一起使用,要求具备 EcoStruxure Control Expert软件的专业知识,,因为它们的实施要求使用 EcoStruxure Control Expert 软件的标准功能(数据编辑器、IODDT 等)。
此外,建议在开发和试运行涉及轴运动实施的应用程序之前,先具备运动控制专业领域的专业知识。 下
fi830f/fi820f/fi810f
Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS,
Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still
It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other
Redundant basic unit pm802f) and can be plugged in and out and replaced online.
Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd
One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one city (subsystem) of industrial “system can
Connect 4960 fieldbus devices (10000 i/0).
Fi820f: two serial interfaces are provided to connect the serial protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association
Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation
Away. And the redundant operation is realized by two redundant field controllers.
Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station
The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured
-Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly.
S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus
Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus
The biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through
IART protocol or field bus (31. 25Kb ProfibusPA and FF bus).
The system communication between the operation management level and the process control level is realized by Di giNetS