IS200WNPSH1A
IS200WNPSH1A
IS200WNPSH1A
F60馈线保护系统是一种集成式保护装置,它以其经济且精巧的设计结构可为馈线同时提供保护、控制、监视和测量。作为UR系列继电器的一员,F60的特点如下:高性能保护功能、可扩展的I/O选择、集成监视和测量功能、高速通讯和强大的编程及配置能力。 B30配备的其它先进的功能包括:断路器失灵保护、CT故障监测、欠电压监视及动态母线仿形。由于其特有的灵活性(终端间CT变比不匹配水平最大可允许32:1),B30是各种不同的母线差动保护方案的最理想的解决方案。为增强在重要保护应用中的安全性,B30可配备可选的冗余双电源。T35变压器保护系统是一种三相变压器保护继电器,用于保护任何容量的、最多具有6个绕组/制动的电力变压器。该继电器提供自动的或用户可定义的用于CT变比匹配的幅值基准绕组选择以及用于各种变压器绕组配置的自动相移补偿功能。T35的算法能够实现用户强制去除零序电流,甚至在三角形连接的变压器绕组的应用情况下,零序电流依然可以去除,这样,就使该继电器能够更好地应用于带有区内电缆联接的变压器或更好地用于带有其他区内接地装置的变压器。
redundant PS. can be switched redundantly.
S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus
Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus
The biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through
IART protocol or field bus (31. 25Kb ProfibusPA and FF bus).
The system communication between the operation management level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard),
Users can choose the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application.
The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform.
tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s
Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance.
System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram
(LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions
Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and an extended library with a large number of 3D symbols.
The system uses the same set of configuration tool software to complete the configuration and debugging of process level, operation level and even fieldbus instruments, and uses the same
a global database.
The scale of the system is highly scalable, and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each