产品目录号1746-F1041,-F104V,-N14,-N1041,-N104V,-N18,NIl61,Nll6V,-N041,和-N04V1746-N14.N1041,N104V,N041,和N04V是4通道模拟输入,输出和组合型模块。这些模块提供了较高的分辨率(16位输入,14位输出)和较好的输入滤波器,从而具有高度的噪音免疫力。组合型I/O模块有助于降低系统成本,并且通过在同一个模块上集成两个模拟量输入通道和两个模拟量输出通道来减少框架的尺寸。
1746-F1041和F104V是2输入/2输出组合型模块,非常适合于模拟量信号快速变化的高速应用系统。尤其适合于设备的压力和位置的控制,例如液压和铸模机械。
1746-N18,N1161和N116V模块是高集成度的8通道和16通道输入模块,最适合于带有大量模拟量输入信号的过程控制的应用场合。这些模块提供了更加快速和更加精确的测量,并且每个通道可以单独组态,增加了系统的灵活性。
content and data in case of power failure.
Basic unit pmbo2f characteristics:
mouth
Installation slots of 4 fieldbus interface cards
c
Installation slot of 2 Ethernet network cards
Support redundant operation of Fieldbus interface card
Support hot plug of Fieldbus interface card
Technical indicators of basic unit pib02f:
CPU :Intel 80960HT25/75
32-bit RISC superscalar processor with operation speed of 150 MIPS
4 MB FLASH-EPROM
EEPROM,serial, 16 Kbit
o
Ram 8 MB (with error check and correction function, abb patent)
16 K internal cache (CPU cache RAM)
Ram backup battery (matchdog, optional redundancy)
Equipment internal temperature monitoring
Watchdog
I/0 sweeping cycle: configurable.
Time required to process 1000 IL (instructions):
< 1.0 ms (processing binary and 16 bit arithmetic instructions)
<2ms (processing fixed-point arithmetic instructions)
< 1.5ms (processing 32-bit floating-point arithmetic instructions)
Bthernet network card ei801f/ei802f/ei803f
The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard)
Interface.
Basic characteristics:
1ee802.3 Ethernet standard
o
Ei801f provides 10base2 thin cable communication interface
Ei802f provides 10BASE5 thick cable connection (through AUI interface)
Ei803f provides 10Base-T twisted pair communication interface
32-bit data bus, 100 mb/s
DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4%
Optional ram backup battery
Fieldbus interface replacement card fi830f/fi820f/fi810f
Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS,
Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still
It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other
Redundant basic unit pm802f) and can be plugged in and out and replaced online.
Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd