Triconex 3805E
Triconex 3805E
Triconex 3805E
介绍了Modicon X80 离散量模块的软硬件实施。
安装模块的一般规则
离散量输入/输出模块诊断处理
BMX DDI 1602 输入模块
BMX DDI 1603 输入模块
BMX DDI 1604T 输入模块
BMX DDI 3203 输入模块
BMX DDI 3232 输入模块
BMX DAI 1602 输入模块
BMX DAI 1603 输入模块
BMX DAI 1604 输入模块
BMX DAI 1614/BMX DAI 16142 输入模块
BMX DAI 1615 输入模块
BMX DAI 0805 输入模块
BMX DAI 0814 输入模块
BMX DDI 3202 K 输入模块
BMX DDI 6402 K 输入模块
BMXDDO 1602静态输出模块
BMXDDO 1612静态输出模块
BMX DRA 0804T继电器输出模块
BMX DRA 0805继电器输出模块
BMXDRA0815继电器输出模块
BMX DRA 1605继电器输出模块
BMX DRC 0805继电器输出模块
BMX DDO 3202 K静态输出模块
BMX DDO 6402 K静态输出模块
BMX DAO1605三端双向可控硅输出模块
BMX DAO1615三端双向可控硅隔离型输出模块
BMX DDM 16022混合静态输入/输出模块
BMX DDM 16025混合继电器输入/输出模块
BMX DDM 3202 K混合静态输入/输出模块
用于离散量I/O模块的TELEFAST 2连接接口链路
Glossary
Process station:
This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant
configuration and non-redundant configuration.
AC800F :
This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2
AC800F controller.
Rack mounted process station:
This term is used to describe a rack-mounted type of process station. A redundant process station contains 2 rack-mounted CPUs.
This term is used to describe a single, non-redundant process station.

In the investment of modern automation system, due to the hardware equipment department
It only takes up less cost in the whole system, then write engineering applications
The cost of software becomes increasingly important. Generally speaking, a self
The engineering application software cost of the automation project accounts for about the entire project.
About 50%, it is not difficult to see that the migration of cost structure creates a lot of innovation for users.
Create an opportunity to optimize project investment, therefore, it is necessary to start from engineering programming
Think about lowering costs in the first place!
This is what we developed the Freelance 800F system for:
Keeping hardware prices consistent with those of programmable logic controllers
In this way, cost efficiency can be improved by reducing user engineering costs.
How the Freelance 800F process control system helps users reduce
Low engineering cost?
●By using a complete engineering tool (Control Builder
F) to configure the entire control system, including automation functions
function, operator interface display and logging, and configuration of the fieldbus.
equipment (PROFIBUS, FOUNDATION Fieldbus,
HART, etc.) and device parameter settings.
● Automatic generation of global data between the process control station and the operator station
According to communication.

For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing
cost and time investment in establishing data communication and interactive access.
And ensure the consistency of data throughout the system.
●Provide system-wide unified inspection of user applications, overriding
from process