可以将 ProSave 安装到 PC 上,出于维护等原因,即使不安装工程组态系统,也可使用 ProSave。 然后在 ProSave 和 PG/PC 接口中指定 HMI 设备和接口的设置。
devices, and one city (subsystem) of industrial “system can
Connect 4960 fieldbus devices (10000 i/0).
Fi820f: two serial interfaces are provided to connect the serial protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association
Modbus Different physical interfaces can be selected for different connection schemes, RS422, RS485, RS232. All interfaces are electrical isolation
Away. And the redundant operation is realized by two redundant field controllers.

Fi8i0f card is a triple can bus protocol interface card (rate 1mbd) used to connect industrial ial “conventional process control station
The i/0 protection unit of the PS is used to receive process signals from the rack mounted i/0 modules supported by the PS. Each field controller PS can only be configured
-Block fi810f card. — The two fi810f interface cards on the redundant PS. can be switched redundantly.

S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus
Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus
The biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through
IART protocol or field bus (31. 25Kb ProfibusPA and FF bus).
The system communication between the operation management level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard),
Users can choose the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application.
The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform.
tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s
Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance.
System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram
(LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system