MVAdvanced MV1000/MV2000便携式无纸记录仪可以广泛应用于工业现场以及研发实验中,性能更好,使用更便捷。MVAdvanced具有强大的单独采集数据的能力,而且连接网络轻松简便,可以将测试数据直接传送到PC机。
– 多通道通用输入
MV1000: 最多24个输入通道
MV2000: 最多48个输入通道
– 连接MW100 DAQMASTER系列可以轻松扩展300个输入通道
– 安全的大容量内存
内存: 400MB
可选择CF卡和USB移动存储媒体
– 可拆卸式输入端子方便现场接线
– 轻便的铝质机身(MV2000)
– 可选择安全的二进制或通用文本数据文件格式
– 先进的网络连接性能,具有Email、文件传送及网络服务器功能
– 使用电池的机型最长可运行约13个小时。
system can handle the application of field equipment maintenance management and cross-plant production management control with ease.
An important member of the Industrial” family, the AC800F system fully embodies the Industrial” (Industrial Information) system pioneered and led by ABB in technology.
information technology) new trends.
The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized
function (operation and display, printing, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems.
can. The process control stage realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control.
Control, sequence control and batch intermittent control functions.
The internal communication of the process control station (between the controller and various intelligent devices such as I/0 or field instruments) adopts the international standard field controller.
Wire. The field controller supports various field buses such as Profibus. Profibus is the most widely used open field bus in the world.
Line international standard, divided into FMS, DP and PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus
The biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through
IART protocol or field bus (31. 25Kb ProfibusPA and FF bus).
The system communication between the operation management level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard),
Users can choose the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application.
The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer