ATV 302 是用于三相鼠笼式异步电机的通用型变频器。 ATV 302 可靠性高,结构紧凑,便于使用,并且符合 EN 50178, IEC/EN 61800-2 标准。适用于大多数常见应用场合.
ATV 302 变频器全系列电路板标配加强涂层,确保各种环境应用稳定运行,并配备有用于正常环境和通风机箱的散热器。多个单元可并排安装在电气柜内以节省空间。
变频器可用于额定值从 0.37kW 到 7.5 kW 的电机,电源从380 V 到 500 V 三相
ATV 302 变频器的人机界面,使用显示屏、菜单导航键和本机控制 (运行/停机和电位计设置的速度给定)。
graphics editing functions:
– Function Block Diagram (FBD)
-Ladder Diagram (LD)
– Instruction List (IL)
– Sequence Control Chart (SFC)
. Structured Text (ST)
●Extensive function block library, user-defined function blocks can also be added
Added to it, the macro library and graphic symbols can be customized for the user.
Blocks can create graphics and operator panels.
●Any standard can be integrated by means of GSD file import
PROFIBUS-DP and PA devices, and through user-defined pairing
dialog box to design the configuration window for these devices.
●Profibus field controller can be integrated through FDT/DTM technology
line equipment

system structure
The Freelance 800F process control system is divided into operator levels
and process control level. The operator level contains controls for operation and display.
Archiving and logging, trending and alarming functions. Controller executes open loop
and closed loop control function.
Freelance 800F DigiVis Operator Level
DigiVis operator stations use PC hardware, either standard commercial
Business PCs can also be industrial-grade PCs and run on Micro-
under soft Windows operating system. DigiVis supports dual-screen display operation
operating technology, that is to say, two operations can be performed using one PC
station and operate with a mouse and a keyboard.
Operator level can install one engineering station and several operators
stand. ControlBuilderF engineering station configures and adjusts the system
Mode. Usually, we can use portable devices such as notebooks to

The system is now configured in the office and on site. Operator-level PC
Can also be used as an engineer station. Engineer standing during system uptime
Intervals can be closed without a permanent connection to the system.
Freelance 800F Process Control Stage
At the process control level, the Freelance 800F system can be controlled by
It consists of a number of process control stations connected to I/O units. you can choose this
Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy
redundant) or non-redundant mode. Modular pluggable input/output modules
Blocks are freely selected and used according to