369-HI-R-M-0-0
369-HI-R-M-0-0
369-HI-R-M-0-0
介绍了 BMXEHC0800 计数模块的软硬件实施。
BMX EHC 0800 计数模块是标准格式模块,能够以最大频率 10 KHz 计数传感器的脉冲。
此模块有 8 个通道。
每个通道上使用的传感器可以是:
·24 VDC 2 线接近传感器
·24 VDC 3 线接近传感器
·具有 10/30 VDC 输出和推拉输出的递增信号编码器。
BMX EHC 0800 模块具有:
·计数相关功能(比较、捕捉、回归、复位为 0)
·为应用程序设计的事件生成功能
·执行器使用的输出(触点、报警、继电器)
information
Global database of Fieldbus equipment, control level and HMI (human-machine interface)
Module identification with production operating parameters
c
Complete self diagnosis
Compact and rugged design
Front panel wiring
DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient
o
Allowable operating ambient temperature 60 C, automatic temperature monitoring
o
EMC (electromagnetic compatibility) conforms to en50082 standard
mouth
Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd
Installation area: Class 1 div 2
The PS supports the following types of fieldbus standards:
Profibus DP,up to 12 MBd
Modbus RTU,1200 to 38. 4KBd
Industrial” CAN I/0 Bus
o
Open CAN -Bus,up to 1 MBd
o
Foundation Fieldbus H1
up to 31. 25KBd
Foundation Fieldbus H2 (fast Ethernet)
HART
The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS.
Industrial “field control explosion (AC800F) consists of the following components:
Basic unit pm802f
Power supply sa801f/sd802f
o
Ethernet network card ei801f/ei802f/ei803f
o
Fieldbus interface card fi810f/fi820f/fi830f
Various accessories
The main components of the field controller PS are described below.
Basic unit pm802f
The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the
The signals of the field bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed
The fieldbus interface card returns the corresponding fieldbus actuator.
Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS
Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be interconnected with each other to form a