PP885 3BSE069276R1
PP885 3BSE069276R1
PP885 3BSE069276R1
西门子过程控制系统组态软件PCS7 V9.1
内含:
□Automation License Manager V6.0 SP9
□STEP7 V5.6 SP2 Upd6
□S7-SCL V5.6 Upd1
□CFC V9.0 SP5 Upd2
□XMLTRANSFER V9.0 SP5 Upd2
□SFC V9.0 SP5 Upd2
□TH V9.0 SP5 Upd2
□IEAPO V9.0 SP5 Upd2
□PCS 7 Basis Library V9.1
□PCS 7 Advanced Process Library V9.1
□VXM V9.0 SP5 Upd1
□VT V9.0 SP5 Upd2
□PCS 7 PID-Tuner V8.0 SP1 Upd2
□AS-OS-Engineering V9.0 SP5 Upd2
□PCS 7 Logic Matrix Engineering Tool V9.1
□PCS 7 Logic Matrix Library V9.1
□PDM V9.2
□PDM FF Option V9.2
□PDM Logon Option V9.2
□PDM Server Option V9.2
□WinCC V7.5 SP2 Upd1
□WinCC OPC UA Server
□WebNavigator Server V7.5 SP2 Upd1
□WebNavigator Remote Publisher V7.5 SP2
□OpenPCS 7 V9.1
□SFC Visualization V9.0 SP5 Upd2
□PV InsInfo-Server V9.0 SP5
□PCS 7 Basis Faceplates V9.1
□PCS 7 Advanced Process Faceplates V9.1
□SIMATIC PCS 7 Logic Matrix Faceplates V9.1
□SIMATIC NET PC-Software V16 Upd4
□BATCH Base V9.1
□BATCH Builder V9.1
□BATCH Client V9.1
□BATCH Fastobjects V9.1
□BATCH Server V9.1
□BATCH WinCC APL Client Options V9.1
□BATCH WinCC Client Options V9.1
□BATCH WinCC Server Options V9.1
□Route Control Base V9.1
□Process Historian Server 2020
□PLCSIM V5.4 SP8 Upd1
□SOFTNET-IE RNA V16 SP1
□SQL Server 2017(WinCC)
□PCS 7 Trial License
□PCS 7 Tools V9.1
communication. For field devices, process control stations and operator stations, a unified global database is used for the entire control system, thereby reducing
cost and time investment in establishing data communication and interactive access.
And ensure the consistency of data throughout the system.
●Provide system-wide unified inspection of user applications, overriding
from process control stations, operator stations to intelligent field devices, including
Including the integrity and consistency check of the user program.
●The programming language strictly complies with the international standard of IEC61131-3, and has
There are high-performance graphics editing functions:
– Function Block Diagram (FBD)
-Ladder Diagram (LD)
– Instruction List (IL)
– Sequence Control Chart (SFC)
. Structured Text (ST)
●Extensive function block library, user-defined function blocks can also be added
Added to it, the macro library and graphic symbols can be customized for the user.
Blocks can create graphics and operator panels.
●Any standard can be integrated by means of GSD file import
PROFIBUS-DP and PA devices, and through user-defined pairing
dialog box to design the configuration window for these devices.
●Profibus field controller can be integrated through FDT/DTM technology
line equipment
system structure
The Freelance 800F process control system is divided into operator levels
and process control level. The operator level contains controls for operation and display.
Archiving and logging, trending and alarming functions. Controller executes open loop
and closed loop control function.
Freelance 800F DigiVis Operator Level
DigiVis operator stations use PC hardware, either standard commercial
Business PCs can also be industrial-grade PCs and run on Micro-
under soft Windows operating system. DigiVis supports dual-screen display operation
operating technology, that is to say, two operations can be performed using one PC
station and operate with a mouse and a keyboard.
Operator level can install one engineering station and several operators
stand. ControlBuilderF engineering station configures and adjusts the system
Mode. Usually, we can use portable devices such as notebooks to
The system is now configured in the office and on site. Operator-level PC
Can also be used as an engineer station. Engineer standing during system uptime
Intervals can be closed without a permanent connection to the system.
Freelance 800F Process Control Stage
At the process control level, the Freelance 800F system can be controlled by
It consists of a number of process control stations connected to I/O units. you can choose this
Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy
redundant) or non-redundant mode. Modular pluggable input/output modules
Blocks are freely selected and used according to the type and number of system process signals.
AC800F controller connects remote I/O or field device via fieldbus
ready.
system communication
Communication between operator level and process control level using TCP/IP
Protocol system bus (based