216DB61 HESG324063R10
216DB61 HESG324063R10
216DB61 HESG324063R10
DPI 515是世界上第一台能够提供自动控制阀门补偿的控制器,可长期持续操作,并适用于各种压力系统容积。设计时特别注重了台面操作或面板安装使用,台面操作型仪表底部装有美观的可伸缩脚,选用架式安装组件可将仪表装入十九英寸面板孔内。单机运动控制
每个驱动器/控制器配备有21个本地I/O端(通过网络可以扩展),使得您的 S2K 单机运动系统成为一个具有多种应用而价格适中的机器控制系统。在一个多轴系统中,通过点对点DeviceNet 通讯一个单独的驱动器/ 控制器可以很容易地控制运动。
分布式运动控制
作为一个网络节点,GE Fanuc运动系统可以接收指令和程序以及来自PC、PLC等的同步数据。当您在接受同类中最佳的运动控制同时,让您可以很灵活地选择前端控制和HMI解决方案。另外,可以利用PLC、单机和智能电机的解决方案。
第三方解决方案
如果您拥有自己的控制器而只需要伺服/步进电机和驱动器,GE Fa nu c 就是您的资源库。保留您原先的控制架构同时选择我们具有宽扭矩范围、卓越性能和绝对可靠的电机/ 驱动器。
diagnosis
mouth
Access to all information from the site, including equipment management information
Global database of Fieldbus equipment, control level and HMI (human-machine interface)
Module identification with production operating parameters
c
Complete self diagnosis
Compact and rugged design
Front panel wiring
DIN rail (U-shaped) mounting well can be directly installed on the wall, which is simple and convenient
o
Allowable operating ambient temperature 60 C, automatic temperature monitoring
o
EMC (electromagnetic compatibility) conforms to en50082 standard
mouth
Certification: CE, Namur, CSA, csa-nrtl, FM class 1 div2, ghost, Lloyd
Installation area: Class 1 div 2
The PS supports the following types of fieldbus standards:
Profibus DP,up to 12 MBd
Modbus RTU,1200 to 38. 4KBd
Industrial” CAN I/0 Bus
o
Open CAN -Bus,up to 1 MBd
o
Foundation Fieldbus H1
up to 31. 25KBd
Foundation Fieldbus H2 (fast Ethernet)
HART
The system allows different types of field buses to be mixed and run simultaneously in the same field controller PS.
Industrial “field control explosion (AC800F) consists of the following components:
Basic unit pm802f
Power supply sa801f/sd802f
o
Ethernet network card ei801f/ei802f/ei803f
o
Fieldbus interface card fi810f/fi820f/fi830f
Various accessories
The main components of the field controller PS are described below.
Basic unit pm802f
The basic unit pm802f is composed of a metal rack and a CPU motherboard. It periodically scans the data from the
The signals of the field bus sensors are processed according to the control application program configured by the user, and then the calculation results are passed
The fieldbus interface card returns the corresponding fieldbus actuator.
Two field controllers can realize controller 1:1 redundancy, and undisturbed switching between master and slave PS. Two on each PS
Ethernet network card, the second network card is used to connect the system network diginets), and the second network cards can be