SCXI-1001 NI
SCXI-1001 NI
SCXI-1001 NI
CP604 控制面板采用彩色TFT 4.3”宽屏触摸屏
CP607 控制面板采用彩色TFT 7”宽屏触摸屏
CP610 控制面板采用彩色TFT 10.1”宽屏触摸屏
CP600-eCo 控制面板将先进的功能和顶尖性能与杰出的设计相结合。设计可为高难度应用提供出色的性价比。它们是工厂自动化和过程自动化中HMI应用的理想选择。
CP600-eCo 控制面板运行 PB610-B 软件。
• 兼容 PB610 – Panel Builder 600。
• 支持全矢量图。本机支持 SVG 图形对象、透明度和透明混合。
• 屏幕对象动态:控制可见性和透明度,移动、调整大小和旋转屏幕上的任何对象。更改基本和复杂对象的属性。
• 采用 TrueType 字体的多语言应用。采用多种语言轻松创建、安装和维护应用以满足全球要求。
• 采用数字、文本、柱状图、模拟仪表和图片格式显示数据。
• 丰富的高级 CP600 功能组合:数据采集和记录,趋势记录,报警处理,调度工具和定时操作(每日和每周调度工具,例外日期),配方,安全和用户管理,电子邮件和 RSS feed。
• 多驱动程序通信功能带来广泛的通信驱动程序选择。
• 利用客户端服务器功能实现远程监控。
• 借助 PB610-B 软件进行离线模拟。
• 强大的脚本语言实现 CP600 应用自动化。高效的脚本调试器提高应用开发生产力。
• 丰富的矢量符号和对象库。
describe the AC800F Field Controller type of process station. A redundant process
station consists of 2
AC800F controller.
Rack mounted process station:
This term is used
to describe a rack-mounted type of process station. A redundant process station
contains 2 rack-mounted CPUs.
This term is used to describe a single, non-redundant
process station.
In the investment of modern automation system, due to the hardware
equipment department
It only takes up less cost in the whole system, then write
engineering applications
The cost of software becomes increasingly important. Generally
speaking, a self
The engineering application software cost of the automation project
accounts for about the entire project.
About 50%, it is not difficult to see that the
migration of cost structure creates a lot of innovation for users.
Create an opportunity
to optimize project investment, therefore, it is necessary to start from engineering
programming
Think about lowering costs in the first place!
This is what we developed the
Freelance 800F system for:
Keeping hardware prices consistent with those of programmable
logic controllers
In this way, cost efficiency can be improved by reducing user
engineering costs.
How the Freelance 800F process control system helps users reduce
Low
engineering cost?
●By using a complete engineering tool (Control Builder
F) to configure
the entire control system, including automation functions
function, operator interface
display and logging, and configuration of the fieldbus.
equipment (PROFIBUS, FOUNDATION
Fieldbus,
HART, etc.) and device parameter settings.
● Automatic generation of global
data between the process control station and the operator station
According to
communication.
For field devices, process control stations and operator stations, a
unified global database is used for the entire control system, thereby reducing
cost and
time investment in establishing data communication and interactive access.
And ensure
the consistency of data throughout the system.
●Provide system-wide unified inspection
of user applications, overriding
from process control stations, operator stations to
intelligent field devices, including
Including the integrity and consistency check of
the user program.
●The programming language strictly complies with the international
standard of IEC61131-3, and has
There are high-performance graphics editing functions:
–
Function Block Diagram (FBD)
-Ladder Diagram (LD)
– Instruction List (IL)
– Sequence
Control Chart (SFC)
. Structured Text (ST)
●Extensive function block library, user-
defined function blocks can also be added
Added to it, the macro library and graphic
symbols can be customized for the user.
Blocks can create graphics and operator panels.
●Any standard can be integrated by means of GSD file import
PROFIBUS-DP and PA devices,