提供Advant Controller 31(AC31 可编程控制器)的使用说明,包括40 和50 系列中央处理单元的整体结构和使用规则。
一个AC31 系统包括至少一个AC31 中央处理单元。而中央处理单元要分有3 种系列:
·40 系列中央处理单元:带有一个本地I/O 扩展接口(最多110 点)
·50 系列中央处理单元:带有一个本地I/O 扩展接口和一个用于远程扩展的CS31 总线接口(最多1000 点开关量 / 222 点模拟量)
·90 系列中央处理单元:带有一个用于远程扩展的CS31总线接口(最多1040 点开关量 / 232 点模块量)
每一个中央处理单元均含有一定数量的I/O 点,可根据不同的中央处理单元以配置更多的I/O,可通过多达6 个开关量/ 模拟量本地扩展模块来增加I/O 点的数量,也可通过CS31 总线的远程扩展模块加I/O 本地扩展模块来增加I/O 点的数量。
symbols can be customized for the user.
Blocks can create graphics and operator panels.
●Any standard can be integrated by means of GSD file import
PROFIBUS-DP and PA devices, and through user-defined pairing
dialog box to design the configuration window for these devices.
●Profibus field controller can be integrated through FDT/DTM technology
line equipment
system structure
The Freelance 800F process control system is divided into operator levels
and process control level. The operator level contains controls for operation and display.
Archiving and logging, trending and alarming functions. Controller executes open loop
and closed loop control function.
Freelance 800F DigiVis Operator Level
DigiVis operator stations use PC hardware, either standard commercial
Business PCs can also be industrial-grade PCs and run on Micro-
under soft Windows operating system. DigiVis supports dual-screen display operation
operating technology, that is to say, two operations can be performed using one PC
station and operate with a mouse and a keyboard.
Operator level can install one engineering station and several operators
stand. ControlBuilderF engineering station configures and adjusts the system
Mode. Usually, we can use portable devices such as notebooks to
The system is now configured in the office and on site. Operator-level PC
Can also be used as an engineer station. Engineer standing during system uptime
Intervals can be closed without a permanent connection to the system.
Freelance 800F Process Control Stage
At the process control level, the Freelance 800F system can be controlled by
It consists of a number of process control stations connected to I/O units. you can choose this
Some process stations are in redundant mode (CPU redundancy, fieldbus module redundancy
redundant) or non-redundant mode. Modular pluggable input/output modules
Blocks are freely selected and used according to the type and number of system process signals.
AC800F controller connects remote I/O or field device via fieldbus
ready.
system communication
Communicatio