XMT868液体流量变送器将最先进的流量测量能力与价格低廉的变送器机型结合在一起,大小只有8.2in(20.1 cm)长,6.6in(16.8cm)宽,重量仅为10lb(4.5kg),可以直接安装在测量点上。这款全数字化的XMT868无可动部件,可提供长期无漂移测量。仪表上的微处理器提供独一无二的数字化信号编码和互相关检测程序,可随液体特性的变化自动调节参数,并可动态配置操作软件以简化编程。 聚台物介质传感器具有电容技术,适用于露点温度在-15℃以上的气体测量。由交叉排列的电极触指、聚台物层、多孔的金属保护层和第二聚合物层构成电容传感元件。聚台物传感器的电容与气体的相对湿度(RH)直接相关。内置的铂温度传感器可以显示独立与相对湿度的温度。
bus in the world
Line international standard, divided into FMS, DP and PA, DP communication rate can be as high as 12MB. Can (din/is011898 standard) bus
The biggest feature is its super robustness and data security. The system also supports MODBUS. The communication with intelligent field instruments is through
IART protocol or fieldbus (31.25kb profibuspa and FF Bus).
The system communication between the operation management level and the process control level is realized by the di ginets network (Industrial Ethernet /iee802.3 standard),
The user can select the communication transmission medium (ordinary cable or optical fiber) and network topology structure according to the actual situation of the application.
Popular PC and MS_ Wi ndows2000 has been widely used in various fields all over the world and has become the de facto standard computer platform
Set. The operating station 0s, engineer station es and data gateway GS of the industrial “system have adopted this platform, thus ensuring the
It is universal, open and easy to use, and brings great convenience for future technology upgrading and maintenance.
System engineering configuration is very convenient. The configuration language is based on ie0611313 industrial standard and provides function block diagram (FBD) and ladder diagram
(LD), instruction list (IL), sequential function diagram (SFC), structured text (st) and other graphical configuration modes. The system contains about 220 functions
The algorithm library of energy block, the basic library with more than 200 graphic symbols and the extended library with a large number of 3D symbols.
The system uses the same set of configuration tool software to complete the configuration and commissioning of process level, operation level and even fieldbus instruments, and uses the same
A global database.
The system scale has strong scalability. The single system supports 1 to 100 control stations and 100 operation stations at most. Each control
The station can support thousands of i/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is all metal enclosure, which can withstand the most
Harsh industrial