PROSOFT 3100-MCM
PROSOFT 3100-MCM
PROSOFT 3100-MCM
SafeRing / SafePlus Air中压干燥空气绝缘环网柜及开关柜, 12 kV, 630A
SafeRing / SafePlus Air是ABB公司推出的环保型气体绝缘环网柜及开关柜,具有环保性能好,可靠性及安全性能高,结构紧凑,免维护等特点。
采用干燥空气作为绝缘介质,干燥空气是一种常用的工业气体,客户不需进行维护及回收。在设备运行过程中出现泄露,不会对环境有任何影响。
SafeRing / SafePlus Air最大程度的继承了现有气体绝缘开关柜成熟的生产工艺和运行经验,能够最大程度的保证产品稳定可靠的运行。
具有较好的环境适应性,可应用于风沙、潮湿、污秽等工业环境中;多个功能单元可密封在同一个气室内,使得结构更紧凑,现场安装工作量更少。
SafeRing / SafePlus Air可集成配电自动化功能,满足智能电网的需求。
redundant PS. can be switched redundantly.
S800 and S900 are distributed i/0 for process control stations. They communicate with their controllers through Prof ibusdp Fieldbus
Communication, which can be installed in the controland PA three levels, DP communication rate can be as high as 12Mb. The CAN (DIN/IS011898 standard) bus
The biggest feature is its super sturdiness and data security. The system of course also supports Modbus. The communication with the intelligent field instrument is through
IART protocol or field bus (31. 25Kb ProfibusPA and FF bus).
The system communication between the operation management level and the process control level is realized by Di giNetS network (Industrial Ethernet/IEEE802.3 standard),
Users can choose the communication transmission medium (ordinary cable or optical fiber) and network topology according to the actual situation of the application.
The popular PC and MS_ Windows 2000 have been widely used in various fields all over the world, becoming the de facto standard computer platform.
tower. The operating station 0S, the engineering station ES and the data gateway GS of the Industrial” system use this platform to ensure the system’s
Versatility, openness and ease of use, and bring great convenience to future technical upgrades and maintenance.
System engineering is very convenient. The configuration language is based on the IE061131 3 industry standard, providing function block diagram (FBD), ladder diagram
(LD), instruction list (IL), sequential function chart (SFC), structured text (ST) and other graphical configuration methods. The system contains about 220 functions
Algorithm library for energy blocks and a basic library with more than 200 graphic symbols and an extended library with a large number of 3D symbols.
The system uses the same set of configuration tool software to complete the configuration and debugging of process level, operation level and even fieldbus instruments, and uses the same
a global database.
The scale of the system is highly scalable, and a single-system supports 1 to a maximum of 100 control stations and 100 operating stations. each control
The station can support several thousand I/0 points at most, and the scale of the whole system can be expanded. The hardware of the system control station is encapsulated in an all-metal shell, which can withstand the most
Harsh industrial environment. The device can be installed either in a cabinet or on a wall. System complies with all current EMC standards and is CE marked
Chi.
Industrial” DCS system