施耐德ATV御程系列柜式变频驱动系统安装手册介绍ATV御程变频驱动系统的机械和电气信息以及关于安装、连线、试运行和维护的说明。
根据客户的需求,IP21、IP23、IP54和IP55防护等级提供壁挂式变频器、内置式变频机柜和落地安装式变频驱动系统等解决方案。
壁挂安装式变频器,0.75kW至160kW
变频驱动系统,110kW至800kW
rate can be as high as 12Mb. Profibus is used to connect intelligent devices such as distributed I/0 stations and field bus instruments.
Communication between the process station, operator station and engineering station takes place via the system bus DigiNetS (Industrial Ethernet). user
Different transmission media (RJ45 twisted pair, thin, thick or fiber optic cables and mixed media) and network topology can be selected for the system bus.
Simple layout, due to the use of TCP/IP protocol, the system can also use the public telephone network (dial-up mode) or satellite to achieve ultra-long-distance communication.
Subsystems such as PLC communicate with the Industrial” system through the ModBus protocol interface. The system also supports IEC870-5 over-control protocol.
discussion.
The Flash EPROM inside the PS provides more than 220 functional modules (control algorithm subroutines), in addition to the basic ones specified in the IEC 61131 3 standard
In addition to this content, many powerful and rigorously tested function blocks from actual engineering applications have been expanded. any complex control
The scheme can be realized by the combination of these function blocks.
The function blocks provided by the system mainly include the following categories:
o
Analog processing
o
digital processing
loop regulation
Logical sequence control
c
logic operation
Monitoring function
Collection function.
c
arithmetic operations
c
TCP/IP protocol communication interface
1EC870-5 protocol communication interface (Telecontrol)
4.2 Field Controller PS
Industrial” field controller PS is a special process control station, which is embedded with field bus communication interface for users to use
Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different),
Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and play
(Plug & Play), and can be plugged and unplugged.
The field controller PS has the following characteristics:
o
Flexible: supports all international standard open fieldbuses and can be mixed
Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd)
Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software
mouth
Access to all information from the field including equipment