51303940-150
51303940-150
51303940-150
WinCC Flexible SMART V4精彩系列人机界面SMART LINE V4,采用西门子 WinCC Flexible SMART V4 进行组态编程。该软件功能强大,并完全兼容原有的SMART LINE V3版本,可实现项目的无缝移植,使您更加轻松便捷地完成工程组态。
最新的WinCC Flexible Smart V4在兼容原有功能的基础上,还支持以下新功能:
▪ 支持S7以太网和串口协议的并行通讯,对于标准Modbus RTU协议设备,支持以SMART LINE作为网关实现数据收发
▪ 全新的表格控件:支持以表格形式显示实时和历史数据
▪ 全新的诊断控件:支持屏上显示S7-200 SMART PLC的系统诊断信息
▪ 组态软件新功能:支持从S7-200 SMART PLC工程文件中自动提取变量并导入
▪ 大幅增加配方及数据记录数量
▪ 全面集成ProSave维护工具
WinCC fleYJble SMART V4操作系统要求:
• Windows 10 Pro Version 20H2(操作系统内部版本 19042.868)及更高版本(64 位)
• Windows 10 Enterprise Version 1809(操作系统内部版本 17763.1821)及更高版本(64 位)
• Windows 10 Enterprise LTSB(操作系统内部版本 17763.1821)及更高版本(64 位)
• Windows 7 Professional SP1(32 位)
• Windows 7 Enterprise SP1(32 位)
• Windows 7 Ultimate SP1(32 位)
industrial” initiated and led by ABB in technology
Information technology) a new trend.
The system is divided into two levels: operation management level and process control level. At the operation management level, not only the traditional control system monitoring operation function is realized
Can (operate and display, print, trend display and alarm), and also complete system hardware diagnosis and data exchange between different systems
Yes. The process control level realizes various loop adjustments including complex control (various PID, ratio, Simith, etc.) and high-speed logic control
Control, sequence control and batch intermittent control functions.
The internal communication of the process control station (between the controller and various intelligent devices such as i/0 or field instruments) adopts the international standard field general
Line. The field controller supports various field buses such as PROFIBUS, which is the most widely used open field bus in the world
Line international standard, divided into FMS, DP and PA, DP communication rate can be as high as 12MB. Can (din/is011898 standard) bus
The biggest feature is its super robustness and data security. The system also supports MODBUS. The communication with intelligent field instruments is through
IART protocol or fieldbus (31.25kb profibuspa and FF Bus).

The system communication between the operation management level and the process control level is realized by the di ginets network (Industrial Ethernet /iee802.3 standard),
The user can select the communication transmission medium (ordinary cable or optical fiber) and network topology structure according to the actual situation of the application.
Popular PC and MS_ Wi ndows2000 has been widely used in various fields all over the world and has become the de facto standard computer platform
Set. The operating station 0s, engineer station es and data gateway GS of the industrial “system have adopted this platform, thus ensuring the
It is universal, open and easy to use, and brings great convenience for future technology upgrading
