CI830 3BSE013252R1 三菱 FR A700系列变频器内置PLC功能说明书(中文)
介绍增加FR-A700 系列变频器FR-A740- □ K-C9 的特殊功能的产品。该变频器软件的规格支持第2 电机控制方法选择功能和累积脉冲监视器功能中的PLG (PLG)模式矢量控制,本规格书中未列出的其它功能与标准FR-A700 系列变频器的相应功能一致。 描述安装在QnPHCPU上的过程控制指令。
过程控制指令具有以下特点。
(1)使用浮点数据
(2)增强的系统调节有效性,通过将微小分块的过程控制指令进行组合来实现PID控制。
(3)应用于大范围控制可自由组合过程控制指令
(4)自动检测警报
(5)PID运算采用速率型不完全微分形式
controller PS is a special process control station, which is embedded with field bus communication interface for users to use
Fieldbus technology offers very flexible options. Each PS allows to insert 4 fieldbus interface cards (the card type can be different),
Each card is connected to 1 field bus to collect process data and diagnostic information from the bus, the interface card is easy to replace and plug and play
(Plug & Play), and can be plugged and unplugged.
The field controller PS has the following characteristics:
o
Flexible: supports all international standard open fieldbuses and can be mixed
Simultaneous connection of 4 high-speed fieldbuses (max. 12 MBd)
Simple engineering: configuration, commissioning and diagnostics using only the same tool CBF (Control Build F) software
mouth
Access to all information from the field including equipment management information
Global database of fieldbus devices, control levels and HMI (Human Machine Interface) usage systems
Module identification with production operating parameters
c
complete self-diagnosis
Compact and robust design
Front Panel Wiring
DIN rail (U-shaped) installation well can be directly wall mounted, simple and convenient
o
Allowable operating ambient temperature…60 C, with automatic temperature monitoring
o
EMC (Electromagnetic Compatibility) according to EN50082
mouth
Certifications: CE, NAMUR, CSA, CSA-NRT
Glossary
Process station:
This term is used to describe AC800F controllers (field controllers) and rack-mounted controllers. A process station can be designed to be redundant
configuration and non-redundant configuration.
AC800F :
This term is used to describe the AC800F Field Controller type of process station. A redundant process station consists of 2
AC800F controller.
Rack mounted process station:
This term is used to describe a rack-mounted type of process station. A redundant process station contains 2 rack-mounted CPUs.
This term is used to describe a single, non-redundant process station.
In the investment of modern automation system, due to the hardware equipment department
It only takes up less cost in the whole system, then write engineering applications
The cost of software becomes increasingly important. Generally speaking, a self
The engineering application software cost of the automation project accounts for about the entire project.
About 50%, it is not difficult to see that the migration of cost structure creates a lot of innovation for users.