TRICONEX 8311N
TRICONEX 8311N
TRICONEX 8311NSLMP是用于CPU模块或外部设备(个人计算机或显示器等)使用以太网对SLMP对应设备进行访问的协议。
如果是通过SLMP的控制步骤可进行报文的发送接收的设备,则可以通过SLMP进行通信。 FX5对应的串行通信功能如下所示。
简易PLC间链接最多连接8台可编程控制器,在这些可编程控制器之间自动进行数据通信。
MC协议MC协议是指使用以太网或串行通信,从CPU模块或外围设备(计算机、人机界面等)访问支持MC协议的设备的协议。
FX5的串行口的情况下,可以使用MC协议的3C/4C帧进行通信。
变频器通信通过RS-485通信,最多可以对16台变频器进行运行控制。
无顺序通信可以与条形码阅读器、打印机、计算机、测量仪器等RS-232C/RS-485接口设备之间进行无协议的串行通信。
通信协议支持可根据对象设备侧(测量仪器、条形码阅读器等)的协议,在对象设备与CPU模块间发送接收数据。
redundancy)
Equipment internal temperature monitoring
Watchdog
I/0 sweeping cycle: configurable.
Time required to process 1000 IL (instructions):
< 1.0 ms (processing binary and 16 bit arithmetic instructions)
<2ms (processing fixed-point arithmetic instructions)
< 1.5ms (processing 32-bit floating-point arithmetic instructions)
Bthernet network card ei801f/ei802f/ei803f
The industrial Ethernet network card provides communication with the system network diginet s (iee802.3 Ethernet standard)
Interface.
Basic characteristics:
1ee802.3 Ethernet standard
o
Ei801f provides 10base2 thin cable communication interface
Ei802f provides 10BASE5 thick cable connection (through AUI interface)
Ei803f provides 10Base-T twisted pair communication interface
32-bit data bus, 100 mb/s
DMA (direct memory access) mode main memory ram, corresponding CPU operating load <4%
Optional ram backup battery
Fieldbus interface replacement card fi830f/fi820f/fi810f
Fieldbus interface cards are divided into several types according to different protocol standards. Each interface card provides – a fieldbus interface (PROFIBUS,
Can, FF, MODBUS, etc.). The configuration and parameter settings of the interface card itself and the field instrument (or remote i1/0) on the connected fieldbus are still
It is designed by the industrial “unified tool control bui lder without additional software. The interface card can be configured redundantly (separated between each other
Redundant basic unit pm802f) and can be plugged in and out and replaced online.
Fi830f: PROFIBUS DP interface card, as the master station, can connect 126 PROFIBUS DP slave stations, and the communication rate can reach 12mbd
One PS can plug in 4 fieldbus interfaces, connect 496 fieldbus devices, and one city (subsystem) of industrial “system can
Connect 4960 fieldbus devices (10000 i/0).
Fi820f: two serial interfaces are provided to connect the serial protocol equipment. The maximum transmission rate is 38.4kbd and can be configured. Its Standards Association
Modbus Different physical interfaces can be selected for different connection schemes,